INSTALLATION
13.300
Ventilation Requirements
The room containing the appliance
should have an air supply in accordance
with BS5440: Part 2
• All rooms require an openable
window, or equivalent, and some
rooms will require a permanent
vent as well.
• For room volumes up to 5m3 an air
vent of 100cm2 is required.
• If the room has a door that opens
directly to the outside, or the room
exceeds 10m3 NO AIR VENT is
required.
• For room volumes between 5m3
and 10m3 an air vent of 50cm2 is
required.
• If there are other fuel burning
appliances in the same room, BS
5440: Part 2: (or equivalent) should be
consulted to determine the air vent re-
quirements.
• This appliance must not be
installed in a bed sitting room of
less than 20m3 or in a bathroom or
shower room.
• Windows and permanent vents
should therefore not be blocked or
removed without rst consulting a
compenent engineer.
LP Gas only - Do not install this
appliance in a room below ground
level. This does not preclude installation
into rooms which are basements
with respect to one side of the building
but open to ground level on the opposite
side.
For installation into environments other
than domestic dwellings, e.g. caravans,
boats and similar - refer to the
relevant standards on ventilation and
gas supply.
Failure to install appliances correctly
is dangerous & could
lead to prosecution.